Resumo do Conteúdo

Página 1 - Thermo Recorder

Thermo RecorderTR-73U© Copyright 2006 T&D Corporation. All rights reserved.2006.12 16004484011

Página 2

1Cautions about using the Sensors[Handling the temperature/humidity sensor]- The temperature/humidity sensor should probably be changed after a perio

Página 3

2About Thermo Recorder TR-73UOutlineTR-73U Thermo Recorder is a data logger capable of measuring, displaying and recording temperature, humidity, and

Página 4 - Explanation of Symbols

3-Battery Life Warning DisplayWhen the battery power becomes low, a battery life warning signal will appear in the unit's LCD display.If the batt

Página 5

4Package ContentsThermo Recorder TR-73U x 1FOR425242262242#5424242#5Copyright 1995-2006 TandDCorporation.

Página 6

5Part Names and FunctionsPart Names and FunctionsFRONT<DISPLAY>button<INTERVAL>button<REC/STOP>buttonDISPLAY ȇ Pressing this butto

Página 7 - CAUTIONS

6LCD DisplayԘԙԚԛԜԝԞӱ Recording MarkThe recording condition will appear.ONȇRecording in progress.ȁBLINKINGȇWaiting for programmed start.Ӳ Data Capacity

Página 8

7Installing the Battery1. Remove the battery cover form the back of the unit.2. Insert 1 AA alkaline battery, making sure that the + and – are in the

Página 9 - Table of Contents

8Installing the USB Device DriverYou will need to install this driver in order to use the device with a USB cable and Windows.The USB device driver mu

Página 10 - -Wetness Detection Sticker

94. By connecting a data logger to the USB cable already connected to your computer, the [Found New Hardware Wizard] will automatically open.* Please

Página 11 - About Thermo Recorder TR-73U

10Checking After Connecting1. Open the [Control Panel] and double click on [System]; the [System Properties] will be displayed.2. Click the [Hardware]

Página 12 - -Adjustment Function

iNotice about this User's ManualIn order to properly use this product, please carefully read this manual before using. T&D Corporation accept

Página 13 - Package Contents

11\Windows® 2000^1. Turn on your computer and open Windows. 2. After Windows has been completely started up, connect the supplied USB cable to a USB p

Página 14 - Part Names and Functions

126. Check [Search for a suitable driver for my device (Recommended)] and click the [Next] button.[Next]buttonCheck7. Check [CD-ROM] and then click th

Página 15 - LCD Display

13Checking After Connecting1. Open the [Control Panel] and double click on [System]; the [System Properties] will be displayed.2. Click the [Hardware]

Página 16 - Turning ON the Power

14[Windows® Me]1. Turn on your computer and open Windows.2. After Windows has been completely started up, connect the supplied USB cable to a USB port

Página 17 - [Windows

15Checking After Connecting1. Open the [Control Panel] and double click on [System]; the [System Properties] will be displayed.2. Click the [Device Ma

Página 18

16[Windows® 98]1. Turn on your computer and open Windows.2. After Windows has been completely started up, connect the supplied USB cable to a USB port

Página 19 - Checking After Connecting

176. Check [Search for the best driver for your device (Recommended)] and click the [Next] button.Check\Next^button7. Check [Specify a location] and c

Página 20

18Checking After Connecting1. Open the [Control Panel] and double click on [System]; the [System Properties] will be displayed.2. Click the [Device Ma

Página 21

19If Installation FailsIf, during USB device driver installation, some trouble occurs that results in a failure to install properly, the following dis

Página 22

20Connecting the SensorsConnect the Sensor*To avoid poor connections, be sure to push the sensor connector securely into the jack.NOTE:If a sensor ext

Página 23

iiFCC Compliance Statement for American UsersThis device complies with Part 15 of the FCC Rules.Operation is subject to following two conditions: (1)

Página 24

21Starting Recording from Main Unit ButtonBy pressing the <REC/STOP> button on the main unit you can start a recording session immediately.*If y

Página 25

22Setting Recording Interval from Main Unit ButtonYou can make or change recording interval settings from the <INTERVAL> button on the front of

Página 26

23Changing the LCD Display Mode from Main Unit ButtonYou can make or change the LCD display settings from the <DISPLAY> button on the front of t

Página 27

24Specifi cationsDevice Type TR-73UMeasurement Items Barometric Pressure Temperature HumidityNumber of Measurement Channels1 Channel 1 Channel 1 Channe

Página 28 - If Installation Fails

Optional AccessoriesTR-07K2 Wall AttachmentWall AttachmentIncluded:screws x 2Ȇdouble-sided tape x 1 46386US-15C USB Communication CableCable Lengthab

Página 29 - Connecting the Sensors

http://www.tandd.co.jp/5652-169, Sasaga, Matsumoto City, Nagano, 399-0033 JapanTel: +81-263-27-2131 Fax: +81-263-26-4281 E-mail: [email protected]

Página 30 - Stop Recording

Customer's name:Address:Phone No.:Dealer's name:Address:Phone No.:Guarantee period 12 months from date of purchaseDate of purchaseStatement

Página 31

iiiSafety Precautions and InstructionsTo ensure safety be sure to obey all of the following warnings.The following items should be strictly obeyed for

Página 32 - Unit Button

ivDANGERSDo not take apart, repair or modify the main unit.Doing so may cause fi re or electrocution.If water or a foreign body enters into this unit,

Página 33 - Specifi cations

vCAUTIONThis unit is not water-resistant.If the unit gets dirty, wipe it with a clean cloth and a mild detergent.Do not expose the unit to harmful gas

Página 34 - Optional Accessories

viCAUTIONSWe shall not guarantee the operation of our device if you have connected it to your computer using a USB hub or a USB extension cable.Batter

Página 35

viiCautions about using the SensorsCautions about using the temperature/humidity sensor TR-3100The sensor can measure temperature within the range of

Página 36 - Statement of Limited Warranty

viiiTable of ContentsNotice about this User's Manual --------------------------------------------------------------------iFCC Compliance Statemen